Table 228. TEST #139 Blue Alarm Inquiry Test — Continued
Error
Test
Code
Result
1795
FAIL
The DS1 Interface circuit pack detects a Payload Loopback Alarm (PLB). If
the DS1 Interface circuit pack connects to a leased T1 facility, call the vendor
of the T1 carrier to diagnose the remote DS1 endpoint. If the DS1 Interface
circuit pack connects directly to another DS1 board, call the system
technician of the remote switch to diagnose the DS1 endpoint.
PASS
Remote DS1 endpoint is in-service. Neither a Blue alarm nor a Line
Loopback alarm nor a Payload Loopback alarm is detected in the DS1
Interface circuit pack.
0
NO
The test could not relate the internal ID to the port (no board).
BOARD
This could be due to incorrect translations, no board is inserted, an incorrect
board is inserted, or an insane board is inserted.
This should re-establish the link between the internal ID and the port.
1096
Issue 5 October 2002
Description/ Recommendation
1. Check to ensure that the board translations are correct. Use the add ds1
UUCSS command to administer the DS1 interface if it is not already
administered.
2. If board was already administered correctly, check the error log to
determine if the board is hyperactive. If this is the case, the board is shut
down. Reseating the board will re-initialize the board.
3. If the board was found to be correctly inserted in step 1, issue the
busyout board command.
4. Issue the reset board command.
5. Issue the release busy board command.
6. Issue the test board long command.
Continued on next page