Avaya DEFINITY Server CSI Maintenance Manual page 1219

Table of Contents

Advertisement

FW-DWNLD (Firmware Download)
Table 276. TEST #1413 Firmware Download Test — Continued
Error
Test
Code
Result
Description/ Recommendation
8
FAIL
The source boards entered on the screen are incorrect. The board
could have been changed after the schedule was entered.
Execute the list config command. verify the source board location.
Execute the change firmware download command and enter the
correct location on the screen.
PASS
Firmware download to this circuit pack is successful.
0
NO
The test could not relate the internal ID to the port (no board). This
BOARD
could be due to incorrect translations, no board is inserted, an
incorrect board is inserted, or an insane board is inserted.
Ensure that the board translations are correct.
If the board was already administered correctly, check the error log to
determine whether the board is hyperactive. If this is the case, the
board is shut down. Reseating the board re-initializes the board.
If the board was found to be correctly inserted in step 1, then issue
the busyout board UUCSS command.
Issue the reset board UUCSS command.
Issue the release board UUCSS command.
Issue the test board UUCSS long command.
This should re-establish the linkage between the internal ID and the
port.
555-233-119
Continued on next page
Issue 5 October 2002
1219

Hide quick links: