Avaya DEFINITY Server CSI Maintenance Manual page 1280

Table of Contents

Advertisement

Table 305. TEST #1406 MP Diagnostic Test — Continued
Error
Test
Code
Result
Description/ Recommendation
16384
FAIL
A SCOTCH device failed:
-
16900
If the board continues to fail replace the board.
24576
FAIL
An ETHERNET device failed:
-
24580
If the board continues to fail replace the board.
PASS
The FPGA device on this TN2302 is operating correctly
0
NO
The test could not relate the internal ID to the port (no board). This
BOARD
could be due to incorrect translations, no board is inserted, an
incorrect board is inserted, or an insane board is inserted.
This should re-establish the linkage between the internal ID and the
port.
1280
Issue 5 October 2002
1. Issue the busyout board UUCSS command.
2. Issue the reset board UUCSS command.
3. Issue the release board UUCSS command.
4. Issue the test board UUCSS long command.
1. Issue the busyout board UUCSS command.
2. Issue the reset board UUCSS command.
3. Issue the release board UUCSS command.
4. Issue the test board UUCSS long command.
1. Ensure that the board translations are correct. Administer the
IPMEDPRO interface if it is not already administered.
2. If the board was already administered correctly, check the error
log to determine whether the board is hyperactive. If this is the
case, the board is shut down. Reseating the board re-initializes
the board.
3. If the board was found to be correctly inserted in step 1, then
issue the busyout board UUCSS command.
4. Issue the reset board UUCSS command.
5. Issue the release board UUCSS command.
6. Issue the test board UUCSS long command.
Continued on next page