Avaya DEFINITY Server CSI Maintenance Manual page 608

Table of Contents

Advertisement

Maintenance Objects
An Administered Connection provides an end-to-end connection between two
access endpoints or data modules. This connection is automatically established
when the administered connection is administered and is due to be active. An
error is logged when an administered connection cannot be established or when
an established administered connection fails. An alarm is logged when a
connection cannot initially be established or fails and cannot be reestablished. An
alarming strategy is supported on a per administered connection basis. An alarm
is raised for a connection when either the number of consecutive failed attempts
to establish the connection reaches the alarm threshold or it can be determined
that a failed attempt to establish was due to an administered error. The alarm
raised ("major," "minor," "warning," or "none") is specified in the "Alarm Type" field
of the Administered Connection Administration screen.
Error Log Entries and Test to Clear Values
Table 29. Administered Connection Error Log Entries
Error Type
0 (a)(b)(c)(k)
1 (a)(b)(c)(d)(e)
2 (a)(b)(c)(f)
6 (a)(b)(c)(g)
16 (a)(b)(c)(k)
17 (a)(c)(h)
18 (a)(b)(c)(i)
21 (a)(b)(c)(g)
22 (a)(b)(c)(d)(j)
28 (a)(b)(c)(d)(e)
29 (a)(b)(c)(k)
31 (a)(b)(c)(g)
34 (a)(b)(c)(l)
38 (a)(b)(c)(m)
40 (a)(b)(c)(l)
41 (a)(b)(c)(m)
42 (a)(b)(c)(l)
43 (a)(b)(c)(q)
608
Issue 5 October 2002
Associated
Aux Data
Test
Any
None
Any
None
Any
None
Any
None
Any
None
Any
None
Any
None
Any
None
Any
None
Any
None
Any
None
Any
None
Any
None
Any
None
Any
None
Any
None
Any
None
Any
None
Alarm
On/Off
Level
Board
Any
OFF
Any
OFF
Any
OFF
Any
OFF
Any
OFF
Any
OFF
Any
OFF
Any
OFF
Any
OFF
Any
OFF
Any
OFF
Any
OFF
Any
OFF
Any
OFF
Any
OFF
Any
OFF
Any
OFF
Any
OFF
Continued on next page
Test to Clear
Value
None
None
None
None
None
None
None
None
None
None
None
None
None
None
None
None
None
None
555-233-119