Avaya DEFINITY Server CSI Maintenance Manual page 673

Table of Contents

Advertisement

ANL-LINE (8-Port Analog Line), ANL-NE-L (8-Port Neon
Analog Line)
Table 49. TEST #48 Station Present Test — Continued
Error
Test
Code
Result
1008
ABORT
1018
ABORT
2000
ABORT
2100
ABORT
FAIL
555-233-119
Description/ Recommendation
Could not allocate a ringing circuit for one of the following reasons:
All the ringing circuits are in use, or
The ringing generator is defective, or
It is not wired correctly.
1. Retry the command at 1-minute intervals a maximum of 5 times.
2. If the test continues to abort, look for RING-GEN errors in the Error
Log. If an ABORT 1008 occurs for Test #48 on other circuit packs as
well, the ring generator may be defective. If it does not occur on other
ports, that circuit pack is currently using all 4 ringing phases.
Test has been disabled via administration. The default for the
on the Station screen is y. Determine why this field has been set to
this station. It may be due to application Test #48, which can disturb users
or terminal operations.
1. To enable the test for the station being tested, enter change station
extension and set the
Response to the test request was not received within the allowable time
period.
System resources required to run this test are not available. Either a
system allocation to get information about the port or to put the port into a
service state failed or the attempt to put the port in connection with a tone
source failed (this could be a tone-clock problem). The tone-clock and tone
detectors could be having a communication problem, for example, the
companding modes could be out of synchronization.
1. Retry the command at 1-minute intervals a maximum of 5 times.
The terminal equipment is not connected to the circuit pack or the ringing
generator may have failed.
1. Remotely test the equipment.
2. If the test fails again, look for RING-GEN errors in the error log. If
present, refer to the RING-GEN (analog ring generator) Maintenance
documentation.
3. Check all of the wiring between the station equipment and the switch,
and run the test again.
4. If the test still fails, the set may be defective. Check the set, and
replace it, if necessary.
5. Some terminal equipment (such as a modem) could fail even when it is
connected properly. If this is the case, use change station extension
and enter n in the Test field to disable the test. This also disables tests
6, 7, 161, 47, and 35 on this port in some systems.
field to y.
Test
Continued on next page
Issue 5 October 2002
field
Test
n
for
673