1006r server description
Server dimensions and weight
Height
Width
Depth (distance from front to back)
Weight of fully loaded system
Environmental specifications
Environmental condition
Operating temperature
Non operating (storage) temperature
Non operating humidity
Altitude
Electrostatic discharge
Acoustic noise
Handling drop (storage)
Handling drop (operating)
Front clearance
Side clearance
Rear clearance
Front panel controls and features
The following diagrams show the front view of the 1006r server chassis. Visible from the front
are the hard drives, optical drive, and system control panel.
10
Avaya CallPilot® 1006r Server Hardware Installation
87.3 mm (3.44 in.)
430 mm (16.93 in.)
704.8 mm (27.75 in.)
29.5 kg (65 lb)
Specification
10°C to 35°C (50°F to 95°F)
Maximum rate of change must not exceed
10°C (50°F) per hour.
-40°C to +70°C (-40°F to +158°F)
90% relative humidity (non-condensing) at
28°C (82.4 °F)
< 1 829 m (6 000 ft)
<= 15 kV
Sound power: 7.0 BA in an idle state
24 in free-fall (when packaged)
2g peak, 11 msec, half sine
50.8 mm (2 in.)
25 mm (1 in.)
92 mm (3.6 in.)
December 2010