4.7 INTERFACE MODE (Cont'd)
Menu
TG3 Series Service Manual
RS-232C CONFIGURATION
This screen allows user to select the RS-232C configurations based on either
the setting on interface board (DIP switch) or the setting of LCD.
BOARD : Priority on current interface board settings.
Select BOARD and press FEED button will proceed directly to RECEIVE
BUFFER or IGNORE CR/LF screen.
LCD : Priority on LCD settings.
Select LCD and press FEED button will continue to BAUDRATE setting.
The initial cursor position is at BOARD.
Note : Changed settings will be in effect from the next power on.
Setting RS-232C baud rate.
Press arrow buttons to set the baudrate as 2400, 4800, 9600, 19200, 38300,
or 57600. Press FEED button to save the setting.
The initial value is 19200.
Note : Changed settings will be in effect from the next power on.
Setting RS-232C parity bit.
The initial value is NONE.
Note : Changed settings will be in effect from the next power on.
Setting RS-232C stop bit.
The initial value is 1BIT.
Note : Changed settings will be in effect from the next power on.
Setting RS-232C character bit.
The initial value is 8BIT.
Note : Changed settings will be in effect from the next power on.
Setting communication protocol.
The following protocols are available when RS-232C interface board is
installed.
1) READY/BUSY
2) XON/OFF
3) STATUS2
4) STATUS3
5) STATUS4
6) STATUS5
The initial value is STATUS4.
When READY/BUSY or XON/XOFF is selected, the printer will proceed directly
to RECEIVE BUFFER menu.
When STATUS5 is selected, the printer will proceed directly to ITEM NO
CHECK menu.
When STATUS2, STATUS3 or STATUS4 is selected, the printer will proceed
directly to IGNORE CR/LF menu.
Note : Changed settings will be in effect from the next power on