4.15 SERVICE MODE (Cont'd)
Menu
TG3 Series Service Manual
SETTING MODE
Displaying the set values of volumes (VR) on the main PCB of the printer.
PITCH : Shows the value of print offset volume.
OFFSET : Shows the value of cut offset volume.
DARKNESS : Shows the value of darkness volume.
Setting print area.
ENABLE : W3.9" (100 mm) x H11.8" (300 mm) TG308
W3.9" (100 mm) x H9.4" (240 mm) TG312
DISABLE : W3.2" (80 mm) x H11.8" (300 mm) TG308
W3.2" (80 mm) x H9.4" (240 mm) TG312
The initial value is DISABLE.
* This setting provides the compatibility with the print position for an existing
XL400e/XL410e. This does not mean that the actual print width becomes 39"
(100 mm). Since an installed print head is 3.2" (80 mm), 0.8" (20 mm), the left
side of the paper will be blank.
Enabling/Disabling the command priority for system setting.
COMMAND : Priority is given to certain system commands that sent to the
printer and which overwrite the configuration done by the LCD
operation panel. This priority assignment affects the settings for
print darkness, print speed, start point correction, operation mode,
printer type, print method and sensor types.
INTERNAL : The above mentioned printer configuration set by the LCD
operation panel is not replaced by the sent command.
The initial setting is COMMAND.
Enabling/Disabling the detection function of stacker/rewinder full.
The initial value is ENABLE.
*No need to change this setting.
This setting is for not detecting an error by lifting the tag hold-down when you
use the rewinder connected with a large or small-sized stacker.
Enabling/Disabling password entry to various modes.
ON : To enable password entry.
OFF : To disable password entry.
The initial value is OFF.
Setting password to go to various modes.
Press
arrow buttons to key in the number and press
/
to move the cursor to next digit. Press FEED button to enter the setting.
Enabling/Disabling the function of nonlock check.
ENABLE : Detects ribbon core not locked.
DISABLE : No detection of ribbon core not locked.
The initial setting is ENABLE.