Section 6: Checks and Adjustment Procedures

6.9 ADJUSTING AND CHECKING SENSORS

In Service Mode, we can check the media sensor condition as well as to calibrate the media sensor level for
the optimum performance.
Enter to MAINTENANCE MODE, select SERVICE MODE and then press
1.
FEED button. Refer to Section 4.14 Maintenance Mode for more details.
Press the
arrow buttons to select SENSOR LEVEL on the SERVICE
2.
/
MODE screen and press the FEED button. The SENSOR LEVEL screen
appears.
Note: The initial cursor position is at SENSOR LEVEL.
Pressing the FEED ,
3.
ONLINE button
FUNCTION
button
ONLINE button
FUNCTION
button
ONLINE button
FUNCTION
button
ONLINE button
FUNCTION
button
ONLINE button
FUNCTION
button
ONLINE button
FUNCTION
button
Return to SERVICE MODE menu
Page 6-12
or
arrow button changes the selection of sensor screen images as shown below.
Select SENSOR LEVEL
+ FEED button
or
button
FEED button
or
button
FEED button
FEED button
FEED button
FEED
button
or
button
FEED button
* Press
,
,
or
button to select
item or set the value accordingly.
The active arrow icons are displayed
on the screen.
or
button
TG3 Series Service Manual