SATO 9001226(A) Service Manual page 166

Tg3 series
Table of Contents

Advertisement

Section 6: Checks and Adjustment Procedures
6.10 ADJUSTING CUTTER SENSORS (Cont'd)
6.10.3 To adjust Edge sensor
Ensure the printer power is turned off. Detach the cutter unit
1.
without disconnecting the connector.
First, lift up the Main cover , unscrew the shaft that holds
the cutter unit in place, removed the shaft and set aside.
Carefully lift and pull out the cutter unit without disconnect
the connector.
Enter to MAINTENANCE MODE, select SERVICE MODE
2.
and then press FEED button. Refer to Section 4.14 Main-
tenance Mode for more details.
In service mode with SENSOR LEVEL highlighted, press
3.
FEED repeatedly until CUTTER SENSOR GAP/CH is
displayed. Then press the
CUTTER SENSOR EDGE.
This screen is to check the sensor responses.
Set the R-corner tag at the cutter sensor, check the LCD
4.
screen display, then pull out the tag and check the screen
again.
The LCD screen will display [0] if the tag is set on the Edge
sensor and display [1] if no tag (R-corner) is set.
If the LCD screen does not response correctly, proceed the
following steps to adjust the sensor level.
Page 6-28
/
arrow buttons to select
3
shaft
1
Cutter unit
TG3 Series Service Manual
2

Advertisement

Table of Contents
loading

This manual is also suitable for:

Tg308Tg312

Table of Contents