Section 6: Checks and Adjustment Procedures
6.9 ADJUSTING AND CHECKING SENSORS (Cont'd)
6.9.3 Side hole Sensor Sensitivity Adjustment
This sensor adjustment regulates penetrating ability for media referencing. The side hold sensor is located at
the Lid latch.
To adjust the Side hole sensor level with the Operator Panel
Note: This calibration is only for fine tuning. There may isn't any significant value changes during adjustment,
depends on the media used. In this case, adjust the sensor level by the VR potentiometer on the Main PCB
(CONT) .
Enter to SENSOR LEVEL setting screen and press the FEED button repeat-
1.
edly until PAPER SENSOR SIDE HOLE is selected.
Press the purple Lid Latch lever to open the hinged Lid Latch . Then, phys-
2.
ically position the tag rests over the side hole sensor and adjust the media
guide to the tag size. Lower and lock the Lid Latch .
Check the sensor response via the LCD screen.
3.
The LCD screen will display [1] if tag is set on the side sensor and display [0] if no tag is set.
Repeat step 2 with the tag taken out and check the LCD screen.
4.
If the LCD screen does not response correctly, proceed to next step to adjust the sensor level.
Press the
arrow buttons to adjust the sensor level and press the FEED button.
5.
/
Enter the value within the range of 0 to 63. The initial value is 31.