7.23 REPLACING CUTTER UNIT

Before replacement, check the Cut counter as explained in Section 6.4 Counter Display Mode .
With the power supply is off, lift up the main cover .
1.
Unscrew the shaft (1) that holds the cutter unit (2) in place, removed the shaft (1) and set aside. Care-
2.
fully lift and pull out the cutter unit (2).
Disconnect the wiring harnesses from the defective cutter unit (2), replace the cutter unit (2) and
3.
reverse the above procedures for reassembly.
Note: Insert the wiring harnesses firmly and arrange the wiring harnesses to ensure that they are not
pinched during installation.
After replacement of cutter unit , perform the following adjustment procedures.
4.
Refer to the Adjustment Procedures section of this manual for the procedures listed below.
1. Cut counter clear function
Refer to Section 6.3 Counter Clear Mode .
2. Adjustment of Cutter sensors
Refer to Section 6.10 Adjusting Cutter Sensors .
3. Adjustment of Cutter timing belt tension
Refer to Section 6.20 Adjusting Cutter Motor Timing Belt Tension .