RealPresence Collaboration Server 800s Administrator's Guide
RMX Time
To ensure accurate conference scheduling, the MCU has an internal clock that can function
in standalone mode, or in synchronization with up to three Network Time Protocol (NTP)
servers.
Guidelines
•
•
Altering the clock
The MCU's date and time can be set manually or enabled to synchronize with external NTP
servers.
To Alter the MCU Time:
1
2
20-4
NTP Version 4 is the only supported protocol.
If applicable, daylight saving adjustments must be implemented by the administrator
whether the MCU is in standalone mode or synchronized with NTP Servers.
On the Collaboration Server menu, click Setup > RMX Time to open the RMX Time
dialog box.
View or modify the following fields:
Table 20-2
RMX Time – Fields Properties
Field
GMT Date
Local Time
GMT Time
Description
The date at Greenwich, UK.
The MCU's local time settings, are calculated from the GMT Time and
the GMT Offset.
The MCU's current GMT Time settings.
Select the Up or Down arrows to alter the GMT Time on the MCU.
Polycom, Inc.