Polycom RealPresence 800s Administrator's Manual page 47

Collaboration server
Hide thumbs Also See for RealPresence 800s:
Table of Contents

Advertisement

Polycom, Inc.
Table 2-11
New AVC CP Profile - Video Settings Parameters (Continued)
Field/Option
Auto Scan Interval(s)
(CP only)
Auto Layout
(CP only)
Table 2-12
Auto Layout – Default Layouts in CP Conferences
Number of Video Participants
0–2
3
4–5
Description
Select the time interval, 10 - 300 seconds, that Auto Scan uses to
cycle the display of participants that are not in the conference layout in
the selected cell.
Auto Scan is often used in conjunction with Customized Polling which
allows the cyclic display to be set to a predefined order for a
predefined time period.
When selected (default), the system automatically selects the
conference layout based on the number of participants currently
connected to the conference. When a new video participant connects
or disconnects, the conference layout automatically changes to reflect
the new number of video participants.
For more information, see Table 2-12 "Auto Layout – Default Layouts
in CP Conferences" on page 2-27.
Clear this selection to manually select a layout for the conference.
The default Auto Layout settings can be customized by modifying
default Auto Layout system flags in the System Configuration file. For
more information see, "Auto Layout Configuration" on page 21-31.
Note: In some cases, the default layout automatically selected for the
conference contains more cells than the number of connected
participants, resulting in an empty cell. For example, if the number of
connected participants is 4, the default layout is 2x2, but as only 3
participants are displayed in the layout (the participants do not see
themselves), one cell is empty.
Auto Layout Default Settings
Chapter 2-Conference Profiles
2-27