Sets the modem initialization string for console serial port modem control software. The default
Modem Configuration String is AT&D0S0=1.
This command is not applicable when the console serial port is configured in TTY mode. The
input will not be accepted or stored when the serial port is configured in TTY mode.
The init command string is used to configure the attached external modem so that dial-in sessions
will be properly accepted by the modem and the connection successfully completed between the
Cajun and the remote system. The set console initcmd is only accepted when the console serial
port is configured as PPP mode. Please read your modem's reference literature to find the correct
AT parameters.
There are few configurations and Lucent-recommended modems that do not require a modem
initialization string.
To Enable:
!
Name
[init_cmd_string]
Cajun(configure)# set console initcmd AT&D0S0=1
Cajun P550/P220 Command Line Interface Reference Guide
set console initcmd [init_cmd_string]
Table 5-4. Parameters, Keywords, Arguments
Definition
An optional parameter, however, when the parameter is
missing, it means that the modem initialization string is
<null>.
Console