Clock Summer-Time Recurring - Lucent Technologies Cajun P550 Cli Reference Manual

Avaya p550: reference guide
Hide thumbs Also See for Cajun P550:
Table of Contents

Advertisement

 *  
    
   
Configures the system to automatically switch to summer time hours (U.S. Daylight
Savings Time). The command format allows for an annual configuration and a one-time
change for a particular year. To disable automatic summer time use the "no" form of this
command. If parameters are excluded for recurring summer time hours, then summer
time is set to default.
 
To Enable:
To Disable:
Name
week
day
month
date
hh:mm
offset
 
Cajun(configure)# clock summer-time recurring 1 Sunday Apr 02:00 2
mon Jan 02:00
Set of recurring summer time hours succeeded
Cajun P550/P220 Command Line Interface Reference Guide
clock summer-time recurring [ <week> <day> <month>
<hh:mm> <week> <day> <month> <hh:mm> [<offset>]]
[no] clock summer-time
Table 14-4. Parameters, Keywords, Arguments
Definition
Week of the month ( 1 to 5 (where 5=last) ).
Day of the week (for example: Sunday, Monday).
Month (for example: January, February).
Date of the month ( 1 to 31 ).
Time (military format) in hours and minutes.
The number of minutes to add during summer time
(default 60). (Optional)
SNMP
14-5

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cajun p220

Table of Contents