DO THE ITEMS BELOW IN THE ORDER LISTED . . . . . . . . . .
At 1B Processor MTC Terminal, Enter Message(s) to Inhibit Peripheral Automatic Exerciser
18
Diagnostics (INH:MACLI,CLASS MTCE;REX!) and Stop Peripheral System (STOP:TEST;PUSYS!)
1. At 1B Processor MTC Terminal, Diagnose: Restore PUB 0 to Service (RST:PUB 0!)
2. Diagnose: Restore PUB 1 to Service
Remove PUB 1 From Service and Power Down PUB 1 at Power Switch of PUBB 0, BAY 1
19
1. Rotate
ROS/OFF Switch to ROS Position
2. Response: OFF/NORM Lamp Is Lighted
3. Depress ROS Switch to Power down PUB 1 at PUBB 0, Bay 1
4. Response: POWER Lamp Is Lighted
20
Remove PUB 1 From Service at Power Switch of IPUB 1 of Frame(s) Determined in Item 5
1. Rotate ROS/OFF Switch to ROS Position
2. Response:
OFF/NORM
21
Remove and Relocate BTR Assemblies and Connect Bus Extension Cables (PUB 1)
Depress ON Pushbutton at PUBB 0, BAY 1 to Restore Power to PUB 1. ( POWER Lamp goes off)
22
23
Execute PUB Looping Test To Verify Extended Bus Branch at BTRs on Growth Frame (PUB 1)
1. Store Input Messages on 1B Processor Terminal for PUB Looping Test
2. Advance Program to Bus Branch To Be Scoped and Set Up Loop To Observe Bit 0 on
PU Write and Reply Buses
3. Scope Bit 0 on PU Write and Reply Buses at BTRs
4. At 1B Processor Terminal, Enter Stop Looping Message (EX:PUB 1!)
5. Advance Program to Bus Branch To Be Scoped and Set Up Loop To Observe Bits 1 to
35 on PU Write Bus, Bits 0 to 11 on PU Enable Address Bus, and Bits 1 to 23 on
PU Reply Bus
6. Scope Bits 1 to 35 on PU Write Bus, Bits 0 to 11 on PU Enable Address Bus,
and Bits 1 to 23 on PU Reply Bus at BTRs
(Continued on Page 8)
EXTEND PUB BRANCH FROM OPERATIONAL FRAME TO
GROWTH FRAME(S) — SUPPORT TO INSTALLER (INST)
(RST:PUB 1!)
Lamp Is Lighted
FOR DETAILS, GO TO
TELCO
DLP-529
TELCO
DLP-523
TELCO
DLP-523
—
TELCO
—
TELCO
—
TELCO
—
TELCO
—
TELCO
—
TELCO
INST
—
TELCO
—
TELCO
DLP-510
TELCO
DLP-511
INST
—
TELCO
—
TELCO
DLP-511
INST
—
Issue 3
DEC 1998
234-353-045
PAGE 7 of 8
NTP
006