REGISTER DETAILS: LOW POWER TIA/POTENTIOSTAT AND DAC CIRCUITS
Table 111. Bit Descriptions for LPTIACON1 (Continued)
Bits
Bit Name
Settings
[12:10]
TIARL
[9:5]
TIAGAIN
[4:3]
IBOOST
analog.com
Description
100 200 kΩ.
101 400 kΩ.
110 600 kΩ.
111 1 MΩ. Recommended value for best DC current measurement performance. Lowest cutoff frequency
setting for low-pass filter.
Set R
.
LOAD
0 0 Ω.
1 10 Ω.
10 30 Ω.
11 50 Ω.
100 100 Ω.
101 1.6 kΩ. R
must be ≥2 kΩ.
TIA
110 3.1 kΩ. R
must be ≥4 kΩ.
TIA
111 3.6 kΩ. R
must be ≥4 kΩ.
TIA
Set R
.
TIA
0 Disconnect R
.
TIA
1 200 Ω. Intended for oxygen sensor. TIA gain resistor is combination of R
Assume R
= 10 Ω. Set by the TIARL bit. R
LOAD
TIA gain is 200.
10 1 kΩ. If R
≤ 100 Ω, R
LOAD
TIA
with a 1 kΩ R
.
TIA
11 2 kΩ. R
gain = 2 kΩ − (R
TIA
LOAD
100 3 kΩ. R
gain = 3 kΩ − (R
TIA
LOAD
101 4 kΩ. R
gain = 4 kΩ − (R
TIA
LOAD
110 6 kΩ. R
gain = 6 kΩ − (R
TIA
LOAD
111 8 kΩ. R
gain = 8 kΩ − (R
TIA
LOAD
1000 10 kΩ. R
gain = 10 kΩ − (R
TIA
1001 12 kΩ. R
gain = 12 kΩ − (R
TIA
1010 16 kΩ. R
gain = 16 kΩ − (R
TIA
1011 20 kΩ. R
gain = 20 kΩ − (R
TIA
1100 24 kΩ. R
gain = 24 kΩ − (R
TIA
1101 30 kΩ. If R
≤ 100 Ω, R
LOAD
TIA
(R
− 100 Ω).
LOAD
1110 32 kΩ. R
gain = 32 kΩ − (R
TIA
1111 40 kΩ. R
gain = 40 kΩ − (R
TIA
10000 48 kΩ. R
gain = 48 kΩ − (R
TIA
10001 64 kΩ. R
gain = 64 kΩ − (R
TIA
10010 85 kΩ. R
gain = 85 kΩ − (R
TIA
10011 96 kΩ. R
gain = 96 kΩ − (R
TIA
10100 100 kΩ. R
gain = 100 kΩ − (R
TIA
10101 120 kΩ. R
gain = 120 kΩ − (R
TIA
10110 128 kΩ. R
gain = 128 kΩ − (R
TIA
10111 160 kΩ. R
gain = 160 kΩ − (R
TIA
11000 196 kΩ. R
gain = 196 kΩ − (R
TIA
11001 256 kΩ. R
gain = 256 kΩ − (R
TIA
11010 512 kΩ. R
gain = 512 kΩ − (R
TIA
Current Boost Control.
00 Normal mode.
gain setting = 100 Ω − R
TIA
gain = (100 Ω − R
) + 1 kΩ. If R
LOAD
LOAD
− 100 Ω).
− 100 Ω).
− 100 Ω).
− 100 Ω).
− 100 Ω).
− 100 Ω).
LOAD
− 100 Ω).
LOAD
− 100 Ω).
LOAD
− 100 Ω).
LOAD
− 100 Ω).
LOAD
gain = (100 Ω − R
) + 30 kΩ. If R
LOAD
− 100 Ω).
LOAD
− 100 Ω).
LOAD
− 100 Ω).
LOAD
− 100 Ω).
LOAD
− 100 Ω).
LOAD
− 100 Ω).
LOAD
− 100 Ω).
LOAD
− 100 Ω).
LOAD
− 100 Ω).
LOAD
− 100 Ω).
LOAD
− 100 Ω).
LOAD
− 100 Ω).
LOAD
− 100 Ω).
LOAD
ADuCM356
and fixed series 110 Ω.
LOAD
+ 110 Ω fixed. Overall
LOAD
> 100 Ω, R
gain is not supported
TIA
> 100 Ω, R
gain = 30 kΩ −
LOAD
TIA
Reset
Access
0x0
R/W
0x0
R/W
0x0
R/W
Rev. A | 92 of 312