Xerox ColorQube 9303 Series Service Manual page 1587

Table of Contents

Advertisement

Figure 4 Test prints orientation
Option 5 - Y Dot Position Correction
The routine ensures that all ink drops are deposited on the drum in the correct location in the
process direction. The routine provides the following options
Select Heads 1, 2, 3 or 4 - Select all printheads unless specifically directed otherwise.
Print test - Select to print test pattern 19. Refer to
Page.
NOTE: Before printing TP 19, ensure that A4 or 8.5 x 11 inch plain paper is loaded LEF
into tray 4. Use the best quality media available. Do not use hole punched paper.
NOTE: TP 19 can be printed to check image quality before or after running the routine.
TP 19 is not scanned when the routine is run.
Start - Select to run the routine.
Before starting the routine:
1.
The machine will perform a head to head alignment.
During the routine:
1.
The test image is printed and scanned on the drum, then cleaned off. No pages are
printed.
ColorQube® 9303 Family
TP 19
Y-Dot Position Correction Test
February 2013
6-295
Option 6 - Reset Head Uniformity Data
The routine deletes the current adjustments (non-recoverable) and restores the manufacturing
settings. Only perform this routine if specifically instructed.
The routine provides the following options:
Printheads 1, 2, 3 or 4 - Select the required printheads.
Start - Select to run the routine.
After completion of the routine:
1.
Perform Printhead Uniformity - Manual (option 1) to re-calibrate the printheads.
Fault Recovery
If the adjustment routine fails or an error is displayed, perform the relevant action in
Table 2 Fault recovery
Fault
A Service Code may indicate faults
with dC972 adjustments.
A generic fault window,
Figure
5.
A fault window with one of these error
messages:
Ink needs to be added.
Load 8.5 x 11 or A4 LEF paper
into a paper tray.
Head purge needs to be per-
formed.
Head to head alignment adjust
needs to be performed.
Drum run out needs to be per-
formed.
A fault window with this warning mes-
sage: Step 1 Unable to Scan Test
Prints - Iteration <#>.
CAUTION
Action
Go to
OF 12
Service Code RAP. Perform the rele-
vant procedures. Correct the service fault, then re-
enter the adjustment procedure at the step that was
interrupted.
The text in the fault window has suggestions for
identifying and correcting common faults. It is not a
checklist of everything that must be corrected. Spe-
cific faults can be:
A calibration related device fault. Refer to
bration Related Device
Faults.
Colour mixing. Go to the
IQ 14
Some Colours
Uneven RAP.
Perform each corrective action, then re-enter the
adjustment procedure at the step that was inter-
rupted.
Perform the corrective actions, then retry the adjust-
ment procedure.
Correctly load the test prints, refer to
Figure
2,
Figure 3
and
Figure
4. Follow the instructions on
the UI.
If the test prints were loaded correctly, check for a
calibration related device fault. Refer to
Related Device
Faults.
General Procedures/Information
Table
2.
Cali-
1,
Figure
Calibration
dC972

Advertisement

Table of Contents