REP 5.1.2 Temperature Control Sensor Assembly

Parts List on PL 5.1
Removal
To avoid personal injury or electrical shock, ensure that the machine is completely off
before disassembling or adjusting. Turn OFF the power and unplug the machine.
The Fuser and Exit Transport are hot. Do not work on them until they are cool enough.
1.
Remove the Fuser (REP 5.1.1).
2.
Slide the Cover to the left and remove (Figure 1).
Figure 1 Removing the Cover
Initial Issue
WorkCentre 5020
WARNING
WARNING
Cover
3.
Remove the Temperature Control Sensor Assembly (Figure 2).
1 Remove the Screw.
2 Remove the Harness.
Screw
Figure 2 Removing the Temperature Control Sensor Assembly
July, 2007
4-31
Harness
Repairs and Adjustments
REP 5.1.2