7.7 Calibrating Swath Compressor Sensor

The swath compressor's sensor can be calibrated by accessing the cab display module's (CDM) WINDROWER SETUP menu.
The calibration procedure must be completed for the sensor to be correctly calibrated. This procedure applies only to
windrowers equipped with a swath compressor.
DANGER
Ensure that all bystanders have cleared the area.
1. Turn the ignition key to the RUN position or start the
engine.
2. Press PROGRAM (A) and SELECT (B) simultaneously on the
cab display module (CDM) to enter programming mode.
• WINDROWER SETUP? will appear on the upper line.
3. Press SELECT (B) until CALIBRATE SENSORS? appears on the
upper line.
• NO/YES will appear on the lower line.
4. Press right arrow (A) to select YES. Press SELECT (B).
• TO CALIBRATE SELECT will appear on the upper line.
5. Press right arrow (A) to scroll through the choices until
SWATH COMPR HT appears on the lower line. Press
SELECT (B).
• SWATH SENSOR CAL will appear on the upper line.
• SWATH UP TO START will appear on the lower line.