7. When the engine temperature is below 5°C (40°F), follow the procedure for a normal start. Refer to Step
but adhere to the following NOTE and IMPORTANT statements while starting the engine.
NOTE:
When starting the engine when the ambient temperature is below 5°C (40°F),the engine will cycle through a period
during which it will sound as though it is struggling to stay running. This is the engine's warm-up mode. The throttle
will be nonresponsive while the engine is in warm-up mode. Warm-up mode lasts between 30 seconds and 3 minutes
depending on the temperature. The throttle will become active after the engine has stabilized and is idling normally.
IMPORTANT:
Do NOT operate the engine above 1500 rpm until the engine's coolant temperature is above 40°C (100°F).
Table 4.3 Engine Start Troubleshooting
Problem
Controls are not in the NEUTRAL position
Operator's station is not locked
Neutral interlock is out of adjustment
Fuel not reaching the engine
Old fuel in the fuel tank
Water, dirt, or air in the fuel system
Improper type of fuel in the fuel tank
Crankcase oil too heavy
Low voltage output from the battery
Poor battery connection
Faulty starter
Wiring is shorted or the circuit breaker is
open
Faulty fuel injectors
Aftertreatment error on start up
262320
PREDELIVERY CHECKS
• Move the GSL to NEUTRAL
• Move the steering wheel to the locked (centered) position
• Disengage the HEADER switch
• Adjust the position of the operator's station
• Ensure that the lock is engaged
• Refer to the windrower's technical manual
• Fill the fuel tank
• Replace the fuel filter
• Ensure that the fuel shut off valve is in the open position
• Drain the fuel tank
• Refill the fuel tank with fresh fuel
• Drain, flush, fill, and prime the fuel system
• Drain the fuel tank
• Refill the fuel tank with the correct type of fuel
• Replace with recommended oil
• Test the battery
• Check the battery's electrolyte levels
• Clean and tighten loose battery connections
• Refer to the windrower's technical manual
• Check the continuity of the wiring and the breaker; manually reset
the circuit breaker
• Contact a MacDon Dealer or MacDon Product Support
• Check diesel exhaust fluid (DEF) coolant hose routing, ensure the
coolant pressure lines, marked with red cable ties, are connected
together, and not crossed with the return line.