To enable or disable certain header sensors:
1. Turn the ignition key to the RUN position or start the
engine.
2. Press PROGRAM (A) and SELECT (C) on the CDM to enter
programming mode.
• WINDROWER SETUP? will appear on the upper line.
• NO/YES will appear on the lower line.
3. Press SELECT (C) until DIAGNOSTIC MODE? will appear on
the upper line.
• NO/YES will appear on the lower line.
4. Press right arrow (B) to select YES. Press SELECT (C).
• VIEW ERROR CODES? will appear on the upper line.
5. Press SELECT (B) until ENTER SENSOR SETUP? appears on
the upper line.
• NO/YES will appear on the lower line.
6. Press right arrow (A) to select YES. Press SELECT (B).
• KNIFE SPEED SENSOR will appear on the lower line.
• ENABLE/DISABLE will appear on the lower line.
7. Press left arrow (B) to enable the selected sensor. Press
right arrow (C) to disable the selected sensor. Press
SELECT (D) to confirm your selection and to proceed to the
next sensor.
These sensors can be enabled or disabled:
• HEADER HT SENSOR
• HEADER TILT SENSOR
• KNIFE SPEED SENSOR
• REEL SPEED SENSOR
• HEADER FLOAT SENSOR
• OVERLOAD PRESSURE SENSOR
• HYD OIL TEMP SENSOR
Press SELECT (D) to display the EXIT SENSOR SETUP?
selection.
6.
Requires installation of optional pressure sensor (MD #B5574).
262320
CAB DISPLAY MODULE
6
252
WINDROWER SETUP?
CXXX
MXXX
A
Figure 7.105: CDM Programming Buttons
DIAGNOSTIC MODE?
CXXX
MXXX
Figure 7.106: Diagnostic Functions
KNIFE SPEED SENSOR
CXXX
MXXX
ENABLE/DISABLE
A
B
Figure 7.107: Header Sensor Setup
NO/YES
C
B
NO/YES
B
A
D
C
C