8. Press right arrow (C) to select YES. Press SELECT.
9. Press PROGRAM (A) to exit programming mode or press
SELECT to proceed to the next diagnostic option.

7.8.3 Displaying Header Sensor Input Signals

Review the output voltage from individual header sensors by accessing the DIAGNOSTIC MODE submenu in the
WINDROWER SETUP menu in the windrower's cab display module (CDM).
NOTE:
The header must be attached to the windrower to perform this procedure. The CDM automatically selects the header
profile based on the type of attached header.
1. Turn the ignition key to the RUN position or start the
engine.
2. Press PROGRAM (A) and SELECT (B) simultaneously on the
CDM to enter programming mode.
• WINDROWER SETUP? will appear on the upper line.
• NO/YES will appear on the lower line.
3. Press SELECT (B) until DIAGNOSTIC MODE? appears on the
upper line.
• NO/YES will appear on the lower line.
4. Press right arrow (A) to select YES. Press SELECT (B).
• VIEW ERROR CODES? will appear on the upper line.
5. Press SELECT (B) until READ SENSOR SETUP? appears on the
upper line.
• NO/YES will appear on the lower line.
262320
CAB DISPLAY MODULE
A
Figure 7.108: CDM Programming Buttons
Figure 7.109: Diagnostic Functions
253
WINDROWER SETUP?
CXXX
MXXX
NO/YES
DIAGNOSTIC MODE?
CXXX
MXXX
NO/YES
B
B
A