MacDon M155 Unloading And Assembly Instructions page 276

Self-propelled windrower
Table of Contents

Advertisement

3. Press SELECT (B) until DIAGNOSTIC MODE? appears on the
upper line.
• NO/YES will appear on the lower line.
4. Press right arrow (A) to select YES. Press SELECT (B).
5. Press SELECT (B) until ACTIVATE FUNCTIONS? appears on
the upper line.
• NO/YES will appear on the lower line.
6. Press right arrow (A) to select YES. Press SELECT (B).
7. Press SELECT (D) until ACTIVATE HDR TILT appears on the
upper line.
• IN/OUT will appear on the lower line.
8. Press and hold left arrow (B) to tilt the header toward the
ground. Press and hold right arrow (C) to tilt the header
away from the ground. Ensure that the tilt functions are
working correctly.
9. Press PROGRAM (A) to exit programming mode or press
SELECT (D) to proceed to the next header function option.
262320
CAB DISPLAY MODULE
MXXX
Figure 7.124: Diagnostic Functions
MXXX
Figure 7.125: Functions
MXXX
A
B
Figure 7.126: Header Tilt Angle
260
DIAGNOSTIC MODE?
CXXX
NO/YES
ACTIVATE FUNCTIONS?
CXXX
NO/YES
ACTIVATE HDR TILT
CXXX
IN/OUT
B
A
B
A
D
C
Revision A