MacDon M155 Unloading And Assembly Instructions page 271

Self-propelled windrower
Table of Contents

Advertisement

3. Press SELECT (B) until DIAGNOSTIC MODE? appears on the
upper line.
• NO/YES will appear on the lower line.
4. Press right arrow (A) to select YES. Press SELECT (B).
5. Press SELECT (B) until FORCE HEADER TYPE? appears on the
upper line.
• NO/YES will appear on the lower line.
6. Press right arrow (A) to select YES. Press SELECT (B).
• SELECT HEADER TYPE will appear on the upper line.
• DISK HEADER will appear on the lower line.
7. Press left arrow (A) or right arrow (B) to cycle through the
list of header types.
8. When the desired header type appears, press SELECT (C).
• EXIT FORCE HEADER? will appear on the upper line.
• NO/YES will appear on the lower line.
9. Press right arrow (B) to select YES. Press SELECT (C).
Proceed to the next diagnostic option, or press PROGRAM
to exit programming mode.
262320
CAB DISPLAY MODULE
Figure 7.112: Diagnostic Functions
Figure 7.113: Header Type
Figure 7.114: Header Type
255
DIAGNOSTIC MODE?
CXXX
MXXX
NO/YES
FORCE HEADER TYPE?
CXXX
MXXX
NO/YES
SELECT HEADER TYPE
CXXX
MXXX
DISK HEADER
A
B
A
B
A
C
B
Revision A