7.6.2 Calibrating Header Tilt Sensor

The header tilt sensor can be calibrated by accessing the cab display module's (CDM) WINDROWER SETUP menu. The
calibration procedure must be completed for the sensor to report the angle of the header correctly.
NOTE:
• The header must be attached to the windrower to perform this procedure. The CDM automatically selects the header
profile based on the type of attached header.
• This procedure is provided on the assumption that the Hydraulic Center-Link kit (MD #B4650) have been installed.
• The engine must be running to perform this procedure.
DANGER
Ensure that all bystanders have cleared the area.
1. Start the engine.
2. Press PROGRAM (A) and SELECT (B) simultaneously on the
CDM to enter programming mode.
• WINDROWER SETUP? will appear on the upper line.
3. Press SELECT (B) until CALIBRATE SENSORS? appears on the
upper line.
• NO/YES will appear on the lower line.
4. Press right arrow (B) to select YES. Press SELECT (C).
• TO CALIBRATE SELECT will appear in the upper line.
5. Press left arrow (A) or right arrow (B) until HEADER TILT
appears on the lower line. Press SELECT (C).
• HDR TILT SENSOR CAL will appear on the upper line.
• EXTEND TILT TO START will appear on the lower line.
262320
CAB DISPLAY MODULE
MXXX
A
Figure 7.87: CDM Programming Buttons
MXXX
A
Figure 7.88: Header Tilt Calibration
244
WINDROWER SETUP?
CXXX
NO/YES
HDR TILT SENSOR CAL
CXXX
EXTEND TILT TO START
B
C