IQ DISPLAY MODULE (IQDM) SERIES 2 AND
IQDM-P DIAGNOSTICS
5. Gradually reduce the armature current limit
6. Quickly reduce the armature current until speed sensor pulses occur
7. Gradually reduce Regen Current Limit
8. SmartKey functions NOT enabled
9. PASSWORD TRIES count incremented
10. Set Internal Scaled Throttle Signal to Zero
11. Turn off Walk Away Relay
12. Activate Walk Away function
13. Activate Walk Away beeping immediately

FAULT RECOVERY

When a fault is detected by the speed controller, the speed controller will attempt to recover from the fault and resume
normal operation. In the case of an intermittent problem such as a loose wiring connection, the controller may be able
to recover and operate normally for a while, but the problem should be repaired before placing the vehicle in service.
Depending on the type of fault, the controller will attempt to recover immediately after the condition clears or after the
accelerator pedal has been cycled (released and pressed again).
CONTROLLER FAULT
01 THROTTLE FAULT 1
02 UNDER VOLTAGE
03 OVERVOLTAGE
04 THERMAL CUTBACK
06 HPD
07 MAIN WELDED
08 RELAY WELDED
09 SPEED SENSOR FAULT
10 MAIN DRIVER ON
11 MAIN COIL OPEN
12 MAIN DROPOUT
13 MOTOR STALL
14 MAIN DRIVER OFF
15 RELAY DNC
16 KEY SWITCH SRO
17 CURRENT SENSE FAULT
18 M-SHORTED
TABLE CONTINUED ON NEXT PAGE
2007-2009 Turf 252, Carryall 252 and XRT 900 Maintenance and Service Manual
TEST WHEN
Continuous
Continuous
Continuous
Continuous
KSI Off/On, F or R on
Contactor commanded open
After Walk Away sequenced
Throttle Applied, Arm PWM > 50%
Continuous while KSI is ON
Continuous while KSI is ON
Throttle applied
Throttle applied
Throttle applied
WalkAway
At controller power up
KSI Off/On, Continuous
Throttle Applied
CONTROLLER RESPONSE
10
5
7
5
10
4
4
4
4
3
3,12
6
3,10
2,13
3
1,2,3
1,2
Faults Menu
RECOVER WHEN
Condition clears
Condition clears
Condition clears
Condition clears
Throttle < 25%
Main or relay successfully opened
Main or relay successfully opened
Speed pulses appear
Condition clears
Condition clears
Throttle applied
Speed pulses appear
Condition clears
Throttle applied
Cycle KSI
KSI Off/On when condition cleared
Throttle Cycled
Page 23-11