Section 13 - Electrical Components: Key-Start With Neutral Rev Gas Vehicle; Starter/Generator; Testing The Starter/Generator; Starter/Generator Removal - Club Car Turf 252 2007 Maintenance And Service Manual

Hide thumbs Also See for Turf 252 2007:
Table of Contents

Advertisement

SECTION 13 – ELECTRICAL COMPONENTS: KEY-START WITH
NEUTRAL REV GAS VEHICLE
DANGER
• See General Warning on page 1-1.
WARNING
• See General Warning on page 1-1.

STARTER/GENERATOR

See General Warning on page 1-1.

TESTING THE STARTER/GENERATOR

See Test Procedure 8 – Starter/Generator (Starter Function) on page 11-17. Also see Test Procedure 11 –
Starter/Generator (Generator Function) on page 11-20.

STARTER/GENERATOR REMOVAL

1.
Make sure the key switch is OFF and the Forward/Reverse handle is in the NEUTRAL position. Chock the wheels.
2.
Disconnect battery and spark plug wire(s). See Disconnecting the Battery – Gasoline Vehicles, Section
1, Page 1-3.
3.
Disconnect the wires from the starter/generator (1). Mark wires before disconnecting. Loosen the pivot nuts (7)
and bolts (5) (Figure 13-1, Page 13-2).
4.
Remove the mounting/adjustment nut (12), washer (9) and bolt (11). Lower the starter/generator and slip the
belt (4) off the pulley (10).
5.
Support the starter/generator so that when the pivot bolts are removed the starter/generator will not fall to the
ground. Remove the two pivot nuts (7) and bolts (5) from the mounting bracket.
6.
Remove the starter/generator.
2007-2009 Turf 252, Carryall 252 and XRT 900 Maintenance and Service Manual
13
Page 13-1

Hide quick links:

Advertisement

Table of Contents
loading