4 Repair
4.3.2 Replacement of cable harness, axes 4-6
Continued
Refitting, cabling axes 4-6
The procedure below details how to refit the cable harness to the axes 4-6.
1
2
3
4
5
6
7
8
9
10
11
12
13
Continues on next page
154
Action
DANGER
Turn off all:
electric power supply
hydraulic pressure supply
air pressure supply (do not turn off for
Foundry Prime robots!)
to the robot, before entering the robot working
area.
Check the position of the three gaskets, located
between the motors and the connection box. Re-
place them if damaged.
Refit the connection box.
Make sure the gaskets are seated properly!
Reconnect all the connectors and reposition the
cabling inside the connection box using straps.
Refit the protection plate in the connection box.
Run the cabling through the lower arm.
Refit the cable bracket at the upper arm.
Refit the cable bracket inside the lower arm.
Feed the cabling through the protection plate and
down through the axis 1.
Refit the cable brackets (A) between the gearboxes
of axes 2 and 3 and strap the cabling.
Refit the cable bracket inside the base.
Put straps around the bundle and position the
cabling at the base according to foldout 4.
Reconnect all the connectors at the base.
© Copyright 2004-2018 ABB. All rights reserved.
Info/Illustration
Part no. is specified in
Required
equipment on page
150.
Connectors and correct positioning
are shown in the figure
Connection
box, upper arm on page
153.
Shown in the figure
Connection box,
upper arm on page
153.
Shown in the figure
Location of cable
harness, axes 4-6 on page
Shown in the figure
Location of cable
harness, axes 4-6 on page
Shown in the figure
Location of cable
harness, view X-X on page
xx0300000113
See chapter Exploded views, in
Product manual, spare parts - IRB
4400.
Product manual - IRB 4400
3HAC022032-001 Revision: Q