[ESC+DC] DataMatrix (ECC200) Data Specify (Compatible
command)
Hexadecimal code
Initial value
Valid range and term of
command
[Function]
Specifying data for DataMatrix (ECC200).
[Format] (Setup part)
<DC>n...n
-
Parameter
n [Print data] = Data
[Coding Example]
Cell width: 02, Cell pitch: 02, Number of cells per line: 000 (Auto setup), Number of cell lines: 000
(Auto setup), Print data: 1234567890
<A>
<V>100<H>200
<BX>01200202000000001
<DC>1234567890
<Q>2
<Z>
[Supplementary Explanation]
-
DataMatrix (ECC200) can specify from 00H to FFH. Note that 05H, 10H, 11H, 12H, 18H, 1BH
cannot be specified because they are printer control codes. When specifying control code for
data, use DataMatrix <2D50>.
[Notes]
-
This command is for the compatibility with previous model.
Data format
* Value in above table shows the maximum number of data that can be specified as barcode data.
ESC
<1B>
16
None
When the power is OFF
Valid range within items
Valid range between items
Data format
Numeric
Alphanumeric
Binary (00H to FFH)
DC
<44>
<43>
16
16
The set parameter is not maintained.
The set parameter becomes invalid.
The set parameter becomes invalid.
3116
2335
1556
294
Parameter
n...n
Number of data