SATO SG112 ex Programming Reference Manual page 28

Hide thumbs Also See for SG112 ex:
Table of Contents

Advertisement

[ESC+V] Vertical Print Position
Hexadecimal code
Initial value
Valid range and term of
command
[Function]
Specifying vertical print position from its start point by dot.
[Format]
<V>aaaaa
-
Parameter
a [Vertical Print Position] = Refer to [Initial Value and Valid Range of Parameter] section below.
[Coding Example]
Vertical print position: 100 dots
<A>
<V>100<H>200<P>2<L>0202<XM>ABCD
<Q>2
<Z>
[Supplementary Explanation]
-
Specifying the start of vertical position for the print of text, barcode, ruled line and graphics.
[Points]
-
Any contents such as text, barcode, graphic exceed printing area will not be printed.
[Initial Value and Valid Range of Parameter]
Initial value: 1
Valid range: 1 to 5040 dots
ESC
<1B>
16
aaaaa=1
When the power is OFF
Valid range within items
Valid range between items
V
<56>
16
The set parameter is not maintained.
The set parameter is valid until the next specification is
made.
The set parameter becomes initial value at the next item
<A>.
27
Parameter
aaaaa

Advertisement

Table of Contents
loading