SATO SG112 ex Programming Reference Manual page 354

Hide thumbs Also See for SG112 ex:
Table of Contents

Advertisement

[ESC+PI] PCX File Registration
Hexadecimal code
Initial value
Valid range and term of
command
[Function]
Specifying the registration of PCX file created by such as Image editing application.
[Format]
<PI>aaa,bbbbb,n...n
-
Parameter
a [Registration number]
Valid Range : 1 to 999
b [Total bytes of PCX file]
Valid Range : 1 to 99999
* Specify the file size of PCX file for total bytes.
n [Data] = PCX file data
* Data is sent as binary data (Outputs 8 bits as one character data all at once)
[Coding Example]
<A>
<CC>1
<PI>001,12345,n...n
<Z>
[Supplementary Explanation]
-
Specify slot number registered with Card Slot for Use <CC> prior to this command <PI> by all
means.
-
Data is sent as binary data (Outputs 8 bits as one font data all at once). Total bytes is PCX file
size and Data is PCX file data.
-
In PCX file, 128 bytes of data is for the header part and the rest of data is for the image data.
-
When [Total bytes of PCX file] is not matching the transfer data, this may become the cause of
malfunction.
-
Total bytes are the file size displayed at [Property] and such.
-
PCX file is available in Black/White mode only. In color mode, printing will not be performed due
to command error. Also, this command is not valid for PCX compressed file. Make sure that the
file extension is set to [PCX] before printing.
-
Specify Card Slot for Use <CC> prior to this command when using.
-
The error occurs when specifying unused or specifying the slot which this product is allocated.
ESC
<1B>
16
None
When the power is OFF
Valid range within items
Valid range between items
PI
<50>
<49>
16
16
The set parameter is not maintained.
The set parameter becomes invalid.
The set parameter becomes invalid.
353
Parameter
aaa,bbbbb,n...n