[ESC+BJT] TrueType Font Call
Hexadecimal code
Initial value
Valid range and term of
command
[Function]
Specifying TrueType Font call.
[Format]
<BJT>,aa,bb,cc,dd,ee,ffff,n...n
-
Parameter
a [Font ID]
b [Horizontal scale factor]
c [Vertical scale factor]
d [Word Pitch]
e [Reserve]
f [Reserve]
[Coding Example]
<A>
<V>100<H>200<CC>1
<BJT>,01,02,02,01,00,0004SATO
<Q>
<Z>
[Supplementary Explanation]
-
Specify the card slot number used for Card Slot <CC> prior to this command.
[Notes]
-
Do not power off this product when accessing to the memory. When this product is turned off
while memory accessing, the data in the accessed media may be corrupted.
ESC
<1B>
16
None
When the power is OFF
Valid range within items
Valid range between items
Valid Range : 00 to 99
Valid Range : 01 to 12
Valid Range : 01 to 12
Valid Range : 00 to 99
Valid Range : 00 (Fixed)
Valid Range : 0000 (Fixed) n [Data]
BJT
<42>
<4A>
<54>
16
16
16
The set parameter is not maintained.
The set parameter becomes invalid.
The set parameter becomes invalid.