[ESC+RD] CG Font
Hexadecimal code
Initial value
Valid range and term of
command
[Function]
Specifying CG font type, font style, font size, and print data.
[Format]
<RD>abc,ddd,eee,n...n
-
Parameter
a [Font type]
      A [CG Times]
      B [CG Triumvirate]
      C [SATOGAMMA] (Code page can be switched by ESC+CE command)
      D [SATOVICA] (Code page can be switched by ESC+CE command)
b [Character set]
      0 No specification for the character set (Fixed) [Font type A or B]
      Refer to [Code page specify parameter] section below. [Other than font type A or B]
c [Font style]
      0 Standard
       1 Bold
       2 Italic
       3 Bold + Italic
d [Width]
      Valid Range: 004 to 999 (dots)
      Valid Range: P02 to P99 (points)
e [Height]
      Valid Range: 004 to 999 (dots)
      Valid Range: P02 to P99 (points)
n [Print data] = Data
 
[Coding Example]
Font type: CG Times
<A>
<V>100<H>100<P>2
<RD>A00,P10,P10,SATO
<Q>2
<Z>
ESC
<1B>
16
b=0
When the power is OFF
Valid range within items
Valid range between items
<RD>
<52>
<44>
16
16
The set parameter is not maintained.
The set parameter becomes invalid.
The set parameter becomes invalid.
103
Parameter
abc,ddd,eee,n...n