[ESC+T2] 24 x 24 dots External Font Registration
Hexadecimal code
Initial value
Valid range and term of
command
[Function]
Registering 24 x 24 dots external fonts.
[Format]
<T2>abbn...n
-
Parameter
a [Registration data selection]
      H: Registration code in HEX character
      B: Registration code in binary code
b [Registration font code address]
      Using Kanji set <KS> command to set Japanese
        JIS code
           H: Up to 95 registrations from "21" to "7F" is available.
           B: Up to 95 registrations from 21H to 7FH is available.
        Shift JIS code
           H: Up to 95 registrations from "40" to "9E" is available.
           B: Up to 95 registrations from 40H to 9EH is available.
      Using Kanji set <KS> command to set other than Japanese
        GB18030, BIG5
           H: Up to 95 registrations from "21" to "7F" is available.
           B: Up to 95 registrations from 21H to 7FH is available.
n [Registered external font data] = Data
[Coding Example]
Registration and printing by binary code
<A>
<CC>0
<T2>B<21>
<00FF...............FF00>
16
<Z>
  
<A>
<CC>0
<V>100<H>200<K2>B<80>
<Q>2
<Z>
ESC
<1B>
16
None
When the power is OFF
Valid range within items
Valid range between items
16
<21>
16
16
T2
<54>
<32>
16
16
The set parameter is not maintained.
The set parameter becomes invalid.
The set parameter becomes invalid.
149