[ESC+2D20] MaxiCode
Hexadecimal code
Initial value
Valid range and term of
command
[Function]
Specifying MaxiCode.
[Format] (Setup part)
<2D20>,a(,bbb,ccc,d...d)
-
Parameter
a [Mode]
2 : Transportation (Numeric)
3 : Transportation (Alphanumeric)
4 : Standard symbol
6 : Reader programing
* Following parameter must be specified when specifying mode 2 or mode 3.
When specifying mode 4 or mode 6, the parameter should be omitted.
b [Service class] = Valid Range : 001 to 999 (Numeric)
c [Country code] = Valid Range : 001 to 999 (Numeric)
d [Postal code] = Valid Range : 0 to 999999999 (Mode 2)
000000 to 999999 (Mode 3)
* Mode 2: Max 9 digits (Numeric only)
Mode 3: Fixed 6 digits (Capital alphabet)
[Format] (Data part)
<DN>mmmm,n...n
-
Parameter
m [Number of Data] = Valid Range : 1 to 138
n [Print data] = Data
* 00H cannot be specified.
Mode
2
3
4
6
ESC
2D20
<1B>
<32>
16
None
When the power is OFF
Valid range within items
Valid range between items
Service class
Country code
Fixed 3 digits
Fixed 3 digits
(Numeric only)
(Numeric only)
Omission
<44>
<32>
<30>
16
16
16
16
The set parameter is not maintained.
The set parameter becomes invalid.
The set parameter becomes invalid.
Postal code
Max. 9 digits
Fixed 6 digits
(Alphanumeric)
218
Parameter
,a(,bbb,ccc,d...d)
Maximum print data
Numeric only
Alphanumeric
123
84
138
93