SATO SG112 ex Programming Reference Manual page 371

Hide thumbs Also See for SG112 ex:
Table of Contents

Advertisement

[ESC+WA] Calendar Print
Hexadecimal code
Initial value
Valid range and term of
command
[Function]
Specifying the print of calendar.
[Format]
<WA>parameter
-
Parameter
a    [Specification of print contents]
      YYYY(Year) Valid Range  :  1981 to 2080
      YY(Year) Valid Range  :  00 to 99
      Y(Year) Valid Range  :  0 to 9
      MM(Month) Valid Range  :  01 to 12
      DD(Day) Valid Range  :  01 to 31
      HH(Hour) Valid Range  :  00 to 11
      hh(Hour) Valid Range  :  00 to 23
      mm(Minutes) Valid Range  :  00 to 59
      ss(Second) Valid Range  :  00 to 59
      TT(AM/PM) Valid Range  :  AM/PM
      JJJ(Julian date) Valid Range  :  001 to 366
      WW(Week) Valid Range  :  00 to 52
      ww(Week) Valid Range  :  01 to 53
[Coding Example]
Specifying and printing out the date that is three months from today.
<A>
<WP>M03
<V>100<H>200
<OB><WA>DD/MM/YYYY
<V>200<H>200
<OB><WA>hh:mm:ss TT
<V>300<H>200
<OB><WA>YY JJJ WW ww
<Q>2
<Z>
[Supplementary Explanation]
-
This command requires optional Calendar IC. This command cannot be used without Calendar
IC.
-
When specifying QTY>2, real-time printing will be performed per label.
-
This command specification is available up to six locations within one form.
ESC
<1B>
16
None
When the power is OFF
Valid range within items
Valid range between items
WA
<57>
<41>
16
16
The set parameter is not maintained.
The set parameter becomes invalid.
The set parameter becomes invalid.
370
Parameter
a

Advertisement

Table of Contents
loading

Table of Contents