SATO SG112 ex Programming Reference Manual page 386

Hide thumbs Also See for SG112 ex:
Table of Contents

Advertisement

[ESC+I#] Exclusive Key Start-End
Hexadecimal code
Initial value
Valid range and term of
command
[Function]
Disable the normal key input temporally and user can specify key exclusively.
The key operation information is stored to the key buffer during the exclusive key function.
The information stored in the key buffer can be acquired by the key information acquisition command
[SOH+KI]. Refer to [Key Information Acquisition Command] below for the details.
[Format]
<I#>a
-
Parameter
a [Exclusive key start-end switch]
       1 : Start exclusive key
       0 : End exclusive key
[Coding Example]
<A>
<I#>1
<IM>1,PRINT   START
<IM>2,PUSH   FEED   KEY
<Z>
(Possible to acquire with the key information acquisition command [SOH+IK])
<A>
<I#>0
<IM>1
<Z>
(Possible to acquire with the key information acquisition command [SOH+IK])
 
ESC
<1B>
16
None
When the power is OFF
Valid range within items
Valid range between items
I#
<49>
<23>
16
16
The set parameter is not maintained.
The set parameter is valid until the next specification is
made.
The set parameter is valid until the next specification is
made.
385
Parameter
a