SATO SG112 ex Programming Reference Manual page 257

Hide thumbs Also See for SG112 ex:
Table of Contents

Advertisement

[Supplementary Explanation]
-
If the parameter other than the description is specified or number of print data does not match,
printing is not performed.
-
When specifying print format, secure more than 2 mm blank space in four sides of the
DataMatrix for read margin for the scanner.
-
When print data is 7EH, specify "7EH, 7EH." Number of data will be "0002."
-
When Auto setup (000) is applied for [Number of cell in one row] and [Number of cell lines],
square DataMatrix is printed.
Data format
* Symbol size of DataMatrix (ECC200) is following 30 types.
Symbol size and number of data of DataMatrix (ECC200)
Number of cells
per 1 line (c)
10
12
14
16
18
20
22
24
26
32
36
40
44
48
52
64
72
80
88
96
104
120
132
144
18
32
26
36
36
48
* Mixture of Numeric, Alphanumeric and Control code varies according to number of characters.
Data format
Numeric
Alphanumeric
Binary (00H to FFH)
Symbol size
Number of Cell
Number of
lines (d)
blocks
10
1
12
1
14
1
16
1
18
1
20
1
22
1
24
1
26
1
32
4
36
4
40
4
44
4
48
4
52
4
64
16
72
16
80
16
88
16
96
16
104
16
120
36
132
36
144
36
8
1
8
2
12
1
12
2
16
2
16
2
The maximum value for the data digit
Numeric
Alphanumeric
6
10
16
10
24
16
36
25
44
31
60
43
72
52
88
64
124
91
172
127
228
169
288
214
348
259
408
304
560
418
736
550
912
682
1152
862
1392
1042
1632
1222
2100
1573
2608
1954
3116
2335
10
20
13
32
22
44
31
64
46
98
72
256
Number of data
3116
2335
1556
Binary
3
1
6
3
6
10
16
20
28
34
42
60
84
112
142
172
202
278
366
454
574
694
814
1048
1302
1556
6
3
8
14
20
30
47

Advertisement

Table of Contents
loading

Table of Contents