SATO SG112 ex Programming Reference Manual page 341

Hide thumbs Also See for SG112 ex:
Table of Contents

Advertisement

[ESC+YS] Format Registration
Hexadecimal code
Initial value
Valid range and term of
command
[Function]
Registering print format.
[Format]
<YS>,aaa
-
Parameter
a [Format registration number]   = Valid Range : 1 to 999
[Coding Example]
<A>
<CC>1
<YS>,1
</N>,3,3
<%>0<V>100<H>200<P>2<L>0101<XM>ABC
<Z>
[Supplementary Explanation]
-
When registering multiple formats, Delimit Start Code <A> and Stop Code <Z> with one format.
-
Specify Card Slot for Use <CC> prior to this command <YS> by all means.
-
Use this command and Registration of Field </N> as a pair.
-
Attempts to re-register with registered No., error will occur, and the targeted content will be
printed.
-
The error occurs when specifying unused or specifying the slot which this product is allocated.
[Notes]
-
Do not power off this product when accessing to the memory. When this product is turned off
while memory accessing, the data in the accessed media may be corrupted.
-
The maximum registration with </N> is 99 fields. (Refer to [ESC+/N] Registration of Field for the
commands can be registered.)
-
The maximum registration with other than </N> is 50 fields. Refer to [Available registration
command] below for the commands can be registered.
ESC
<1B>
16
None
When the power is OFF
Valid range within items
Valid range between items
YS
<59>
<53>
16
16
The set parameter is not maintained.
The set parameter is valid until the next specification is
made.
The set parameter is valid until the next specification is
made.
340
Parameter
,aaa