SATO SG112 ex Programming Reference Manual page 69

Hide thumbs Also See for SG112 ex:
Table of Contents

Advertisement

[ESC+RI] Label Size
Hexadecimal code
Initial value
Valid range and term of
command
[Function]
Specifying parameters relative to label size.
[Format]
<RI>aaaa,bbbb,cc,dd,eeee,ffff,gg,hh
-
Parameter
a [Sheet width] = Valid range : 1500 to 3200 (dots)
b [Sheet length] = Valid range : 480 to 3600 (dots)
c [Horizontal distance between labels] = Valid range : 00 to 60 (dots)
d [Vertical distance between labels] = Valid range : 00 to 60 (dots)
e [Small label width] = Valid range : 480 to 3200 (dots)
f [Small label length] = Valid range : 480 to 3600 (dots)
g [Label width quantity] = Valid range : 01 to 60
h [Label length quatity] = Valid range : 0 to 07
[Coding Example]
<A>
<RI>2196,1440,24,36,0700,0480,03,03
<A1>14402196
<RW>02
<Z>
 
Print result
ESC
<1B>
16
None
When the power is OFF
Valid range within items
Valid range between items
f
e
d
a
RI
<52>
<49>
16
16
The set parameter is not maintained.
The set parameter is valid until the next specification is
made.
The set parameter is valid until the next specification is
made.
b
c
68
Parameter
aaaa,bbbb,cc,dd,eeee,ffff,gg,hh