SATO SG112 ex Programming Reference Manual page 40

Hide thumbs Also See for SG112 ex:
Table of Contents

Advertisement

[ESC+FC] Print Circle
Hexadecimal code
Initial value
Valid range and term of
command
[Function]
Specifying the print of circle.
[Format]
<FC>,aaa,bbb(,c,d)
-
Parameter
a [Radius] = Valid range : 5 to 999 dots
b [Line width] = Valid range : 1 to 999 dots
c [Sectional number] = Valid range : 0 to 8 When omitted: 0 (omissible)
*See the details listed below.
d [Pattern] = Valid range : 0 to 3 When omitted: 0 (omissible)
      0 : Solid line (black)
      1 : Gray 1
      2 : Gray 2
      3 : Gray 3
-
Sectional number
Section 0
Section 1
[Coding Example]
Solid line circle of 100 dots in radius, 8 dots in line width
<A>
<V>200<H>200
<FC>,100,8,0,0
<Q>1
<Z>
ESC
<1B>
16
None
When the power is OFF
Valid range within items
Valid range between items