[ESC+/N] Registration of Field
Hexadecimal code
Initial value
Valid range and term of
command
[Function]
Registering items within the field of Registration of Format <YS>.
[Format]
</N>,aa,bb
-
Parameter
a [Field number] = Valid Range : 1 to 99
b [Digit number of print] = Valid Range : 1 to 99
[Coding Example]
<A>
<CC>1
<YS>,1
</N>,1,3
<%>0<V>100<H>200<P>2<L>0101<XM>ABC
</N>,2,5
<%>0<V>200<H>200<P>2<L>0101<OA>12345
</N>,3,8
<%>0<V>300<H>40<B>40208049123456
<Z>
[Supplementary Explanation]
-
Specify the value of [Field number] in ascending order.
-
Specify Vertical Print Position <V> and Horizontal Print Position <H> for each field. If not, initial
value will be set.
-
Specification of digit number when printing external character.
External code H, one external character has 4 digits; thus, three external characters make 12
digits for printing.
External code B, one external character has 2 digits; thus, three external characters make 6
digits for printing.
-
Use this command and Registration of Format <YS> as a pair.
-
Due to the memory capacity limit, it may not save up to 99 registries.
-
The error occurs when specifying unused or specifying the slot which this product is allocated.
ESC
<1B>
16
None
When the power is OFF
Valid range within items
Valid range between items
/N
<2F>
<4E>
16
16
The set parameter is not maintained.
The set parameter is valid until the next specification is
made.
The set parameter is valid until the next specification is
made.