The data receive waiting status of this command can be released with the following cancel the
operation.
Send CAN to the data port
Print job cancel by LCD menu operation ([OFFLINE] -> [CANCEL] -> [YES] -> [ENTER])
-
Note that 00H is specified as terminate code for the specified digit when terminate code is
specified and terminate code itself is omitted.
-
The time out time is waiting time for 1 byte receive data. Monitoring time is cleared at every 1
byte receive, and wait for the specified time again for receive. This is repeated for the specified
receive digits.
-
When the time to receive is out, store the received byte to the internal buffer and stop the
command operation. The digit item in the internal buffer will be the actual received bytes, not the
specified digits.
-
When the time to receive is out, the command finishes normally even the data are not enough
for the specified receive data.
-
When the command finished due to the receive timeout while receiving terminate code, already
received terminate code may be stored in the internal buffer. In this case, set longer timeout
time.
-
When received data are less than the specified [acquire digit], the printer will wait receiving for
the specified [timeout time].
-
When the received data are more than the [acquire digit], the data for the acquire digit are
stored in the internal buffer and rest are remained in the receive buffer. These can be stored in
the internal buffer by using Internal Buffer Registration (received data) <IR> again.