[ESC+PS] Proportional Pitch
Hexadecimal code
Initial value
Valid range and term of
command
[Function]
Specifying the proportional pitch.
[Format]
<PS>
[Coding Example]
<A>
<PS>
<V>100<H>200<P>2<L>0202<XM>ABCD
<Q>2
<Z>
[Supplementary Explanation]
-
If specifying this command, width of alphanumeric becomes narrower than the time when <PS>
was not specified.
-
If data other than specified is set, proportional print will not be performed.
[Valid Commands]
Font
<X21>
<XU>
Modification
<RF>
ESC
<1B>
16
Proportional
When the power is OFF
Valid range within items
Valid range between items
<X22>
<X23>
<X24>
<XS>
<XM>
<XB>
PS
<50>
<53>
16
16
The set command is not maintained.
The set command is valid until the next specification is
made.
The set parameter becomes initial value at the next item
<A>.
<XL>
<RD>
<$=>
31
Parameter
None