[ESC+&] Store Form Overlay
Hexadecimal code
Initial value
Valid range and term of
command
[Function]
Specifying the registration of form overlay.
[Format]
<&>(aab...b)
-
Parameter
a [Registration key] = Valid range : 01 to 99 (omissible)
b [Comment] = Max. 16 bytes (omissible)
[Coding Example]
<A>
<V>100<H>50<FW>1010V800H750
<V>100<H>50<FW>0505V760H710
<V>150<H>100<XB>0MODEL
<&>01DATA1
<Z>
[Supplementary Explanation]
-
This command saves fixed print contents to the printer and then, Recall Form Overlay </>
combines the contents with drawing of general data to print out.
-
Specify this command at the end of data string that is to be stored. Drawing valid range in form
overlay registration is same as printing area.
-
This command can register only one format. Use any code from 01 to 99 as a registration key.
-
To change contents, specify Clear Form Overlay (<*>&), and then register new storage data.
-
Invoke registered contents by Recall Form Overlay </>.
-
When specifying Media Size <A1>, it will be extracted in the specified area.
ESC
<1B>
16
None
When the power is OFF
Valid range within items
Valid range between items;
&
<26>
16
The set command is not maintained.
The set command is valid until the next specification is
made.
The set command is valid until the next specification is
made.