SATO SG112 ex Programming Reference Manual page 26

Hide thumbs Also See for SG112 ex:
Table of Contents

Advertisement

[ESC+WK] Job Name
Hexadecimal code
Initial value
Valid range and term of
command
[Function]
Specifying job name for status return.
[Format]
<WK>aaaaaaaaaaaaaaaa
-
Parameter
a [Job Name] = ASCII code 16-digit, Shift JIS Kanji 8-digit
[Coding Example]
Job name: SATO
<A>
<ID>01
<WK>SATO
<V>200<H>100<P>0<$>B,100,100,6
<$=>SATOPRINTER
<Q>2
<Z>
[Supplementary Explanation]
-
When Status4 is used for interface protocol, specified job name can be set to the telegraphic
status.
-
Status can be confirmed by sending status request (ENQ).
-
Include this command within items and use between Start Code <A> and Stop Code <Z>.
-
This command can be used in combination with Job ID Number <ID>.
[Points]
-
In status return interface protocol, this command becomes valid when status request (ENQ) is
received while printing (QTY≠0, includes at the time of Offline and Error).
-
In status return communication protocol, if status request (ENQ) is received when printing is not
in progress (QTY=0, No received data when power is ON), space (20H) will be set to status and
returned.
-
When Job name <WK> is used more than twice within the items of Start Code <A> and Stop
Code <Z>, the last specified value becomes valid.
-
For more information, refer to the "Interface Specifications."
ESC
<1B>
16
aaaaaaaaaaaaaaaa=<20>
When the power is OFF
Valid range within items
Valid range between items
WK
<57>
<4B>
16
16
16
The set parameter is not maintained.
The set parameter is valid until the next specification is
made.
The set parameter becomes invalid.
25
Parameter
aaaaaaaaaaaaaaaa

Advertisement

Table of Contents
loading

Table of Contents