SATO SG112 ex Programming Reference Manual page 200

Hide thumbs Also See for SG112 ex:
Table of Contents

Advertisement

[ESC+BL] ~ [ESC+d] UPC-A Barcode (Specifying HRl)
Hexadecimal code
Initial value
Valid range and term of
command
[Function]
Set the height of character barcode of the first digit and the last digit to the same height of the guard
bar.
[Format]
<BL>abbcccn...n ~ <d>n...n
-
Parameter
a [Barcode type] = H : UPC-A (Fixed 'H')
b [Narrow bar width] = Valid range : 01 to 12 dots
c [Height of barcode] = Valid range : 001 to 999 dots
n [Print data] = Data : Fixed 11 digit
d [Font type]
      OA
      OB
      XU
      XS
      XM
      XB
      XL
n [Print data] = HRI data   :   fixed 12 digits
[Coding Example]
Barcode type: UPC-A, Narrow bar width: 02, Barcode height: 120, Barcode data: 01234567890,
Font type: XS, HRI data: 01234567890
<A>
<H>100<V>100<BL>H0212001234567890
<XS>01234567890
<Q>2
<Z>
ESC
<1B>
16
None
When the power is OFF
Valid range within items
Valid range between items
BL ~ d
<42>
<4C>
~ character
16
16
type
The set parameter is not maintained.
The set parameter becomes invalid.
The set parameter becomes invalid.
199
Parameter
abbcccn...n ~ <d>n...n