[ESC+IZ] Key Input
Hexadecimal code
Initial value
Valid range and term of
command
[Function]
Store the data input from the operation panel to the internal buffer.
Change the data with [↑] [↓] keys and move the cursor with [←] [→] keys.
Fix the input value with the [ENTER] key and store it in the internal buffer. The display transit in this
state.
It is possible to store input data up to 32 digits for 16 blocks in the internal buffer (RAM).
The stored data can be recalled by Internal Buffer Recall <IB> to be used as print data.
[Format]
<IZ>aa,bb,cc,ddd...d
-
Parameter
a [Internal buffer number] = Valid range : 1 to 16
b [Input digit] = Valid range: 1 to 32
c [Initial data] = For number of digits specified by b (Display available range: ASCII 20H-7EH)
d [Data item name] = Valid range : Only alphanumeric and symbols 16 digits
ESC
<1B>
16
None
When the power is OFF
Valid range within items
Valid range between items
IZ
<49>
<5A>
16
16
The set parameter is not maintained.
The set parameter becomes invalid.
The set parameter becomes invalid.